EMG Biofeedback Stimulation Device XY-K-SWFK-VIII
Model Number: XY-K-SWFK-VIII
Type: Health Care Product
Product Brand: Sunnyou
Recharger Input: 100V-240V 50Hz- 60Hz
Electrode Cable: 1400mm
Warranty: 1 Year
Application: Rehabilitation Centre
The electromyographic biofeedback stimulator collects weak signals from the patient’s limb surface electrodes, filters and processes them to extract signals expressing the patient’s voluntary electromyography and muscle strength. Based on the magnitude of electromyographic feedback, it synchronously outputs electrical stimulation of the same intensity. Through electrode stimulation, specific muscle contraction movements in the patient’s paralyzed limb are elicited, thereby achieving functional training for autonomous movement in the paralyzed limb.
Advantages
1. Bluetooth communication:
After iPad sends command signal, the Stimulator should be able to pair and connect with it. After successful connection, the Stimulator will display Bluetooth icon; The Bluetooth communication range between the stimulator and iPad is greater than 5 cm and less than 10 meters in open areas.
2. Game Mode:
Enter Multimedia Feedback Mode (GAME).
In game mode, there are 6 games to choose from, for strength training, endurance training and coordination training.
The user controls the game by contracting muscles to generate EMG signals. Playing interactive games with APP while doing repetitive and boring muscle training makes the rehabilitation training full of fun.
Scope of Application
It is used as an auxiliary training for patients with upper limb dysfunction caused by stroke.
Usage Precautions
- Operation of the stimulator must be conducted by trained medical personnel.
- It must not be used simultaneously with high-frequency surgical equipment, shortwave, microwave, or similar devices.
- Electrode pads should not be placed simultaneously in front of and behind the heart. Placing electrode pads near the chest increases the risk of cardiac fibrillation.
- After placing electrode pads on the body, do not switch on the stimulator immediately to avoid momentary electric shock. Therefore, fix the electrode pads after turning on the power switch and remove them before turning off the power switch.
- Children, elderly individuals, emergency patients, and those incapable of self-care should use the device under the supervision of a doctor.
- During treatment, avoid moving positions or pulling on electrode wires arbitrarily to prevent poor contact.
- During therapy, intensity should follow the principle of starting from a low level and gradually increasing, based on the patient’s tolerance.
- In case of malfunctions, please contact Xiangyu customer service for repair.
Product Parameters
Product | Electromyographic Biofeedback Stimulator |
Electrode Cable | 1400mm |
Electrode Sheet | Φ50mm |
Frequency of Electrical Signal | 20-500Hz |
System Noise | ≤1μV |
Differential Mode Input Impedance | > 5MΩ |
Common Mode Rejection Ratio | > 100dB |
Feedback Threshold | 10μV~1000μV |
Pass Band | 20Hz~500Hz |
Power Frequency Notch | 50Hz |
Charger Input | 100V~240V,50Hz~60Hz |
Battery Capacity | 3500mAh |
Frequency | 2Hz ~ 100Hz |
Threshold Value | 10μV~50μV/10μV~200μV/10μV~1000μ |